Mostrar el registro sencillo del ítem
dc.contributor | Nuria Patiño-Marín;0000-0003-0056-5901 | es_MX |
dc.contributor.advisor | Patiño Marín, Nuria | es_MX |
dc.contributor.author | Ferretiz Briones, Julio | es_MX |
dc.coverage.spatial | México. San Luis Potosí. San Luis Potosí. | es_MX |
dc.creator | Julio Ferretiz Briones;CA1375171 | es_MX |
dc.date.accessioned | 2024-08-09T13:25:21Z | |
dc.date.available | 2024-08-09T13:25:21Z | |
dc.date.issued | 2024-08-08 | |
dc.identifier.uri | https://repositorioinstitucional.uaslp.mx/xmlui/handle/i/8741 | |
dc.description.abstract | Introducción: Al trabajar en la cavidad oral se está expuesto a fluidos como sangre y saliva, los cuales pueden contener virus y bacterias que representan un riesgo de infecciones cruzadas para el odontólogo y para las personas usuarias, por lo que resulta crucial el llevar a cabo procedimientos adecuados de esterilización que garanticen que tanto el instrumental como las piezas de mano estén libres de microorganismos. Objetivo: Identificar la frecuencia de respuestas correctas de los alumnos de Servicio Social de la licenciatura de Odontología del Estado de San Luis Potosí, sobre el proceso de esterilización. Material y métodos: Se realizó un estudio transversal y prolectivo, con la participación de 174 alumnos de servicio social, los cuales contestaron un cuestionario digital sobre el tipo, uso, verificación y mantenimiento de los equipos de esterilización. Para el análisis datos se utilizó estadística descriptiva de cada una de las preguntas obteniendo la frecuencia de respuestas correctas y estas se reportaron por secciones del cuestionario para una mejor comprensión. Resultados: La frecuencia general de aciertos fue de 16 de 22 preguntas, representando un promedio de 73% de aciertos. Se documentó que el 98% de los participantes utiliza el autoclave para la esterilización de su instrumental, y en el área del uso del equipo, solo el 60% respondió correctamente los niveles adecuados que se utilizan en los equipos de esterilización. En relación con la verificación del equipo, el 54% de los alumnos participantes no conocen los indicadores biológicos (IB) y solo el 26% conoce la frecuencia de uso de los IB indicada en la NOM-013-SSA-2015. Conclusiones: Se observó una frecuencia baja respuestas correctas con relación al procedimiento para utilizar los equipos de esterilización y la monitorización o verificación de los equipos de esterilización. | es_MX |
dc.description.abstract | Introduction: Working in the oral cavity exposes dental professionals to fluids such as blood and saliva, which may contain viruses and bacteria, posing a risk of cross-infections. Therefore, proper sterilization procedures are crucial to ensure that both instruments and handpieces are free from microorganisms. Objective: To identify the frequency of correct responses among Social Service students in the Dentistry program at the State of San Luis Potosí regarding sterilization processes. Materials and Methods: A cross-sectional and prospective study was conducted involving 174 Social Service students. They completed a digital questionnaire on the types, usage, verification, and maintenance of sterilization equipment. Descriptive statistics were used to analyze the data, reporting frequencies of correct responses for each questionnaire section. Results: The overall frequency of correct answers was 16 out of 22 questions, representing an average of 73% correct responses. It was documented that 98% of participants use autoclaves for instrument sterilization. Regarding equipment usage, only 60% correctly identified the appropriate settings used in sterilization equipment. Concerning equipment verification, 54% of participants were unfamiliar with biological indicators (BI), and only 26% knew the recommended frequency of BI usage according to NOM-013-SSA-2015. Conclusions: There is a low frequency of correct responses regarding the procedures for using sterilization equipment and monitoring or verifying its effectiveness. | es_MX |
dc.description.statementofresponsibility | Autoridades que crean políticas | es_MX |
dc.description.statementofresponsibility | Investigadores | es_MX |
dc.description.statementofresponsibility | Personal de apoyo escolar | es_MX |
dc.description.statementofresponsibility | Estudiantes | es_MX |
dc.description.statementofresponsibility | Educadores | es_MX |
dc.language | Español | es_MX |
dc.publisher | Facultad de Enfermería y Nutrición | es_MX |
dc.relation.ispartof | REPOSITORIO NACIONAL CONACYT | es_MX |
dc.rights | Acceso Abierto | es_MX |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0 | es_MX |
dc.subject | Bacterias, conocimiento, cuestionarios, esterilización, estudiantes, servicio social | es_MX |
dc.subject | Bacteria, knowledge, questionnaires, sterilization, students, social service. | es_MX |
dc.subject.other | MEDICINA Y CIENCIAS DE LA SALUD | es_MX |
dc.title | Conocimiento de los alumnos de servicio social de las licenciaturas de odontología del Estado de San Luis Potosí, sobre el tipo, uso, verificación y mantenimiento de los equipos de esterilización | es_MX |
dc.type | Tesis de maestría | es_MX |
dc.degree.name | Maestría en Salud Pública | es_MX |
dc.degree.department | Facultad de Enfermería y Nutrición | es_MX |